Category: 23

Program affectedPIPE-FLO® Professional

...

The System Summary report in PIPE-FLO® Professional 16 was adapted to included additional calculations for Tank Liquid Volume and Overall System Liquid Volume 

Workaround

calculate Total System Liquid Volume from Total Pipeline Liquid Volume and Total Tank Liquid Volume. However, the Total Pipeline Liquid Volume was not updated to just take into account liquid only pipelines and was including gas pipelines in the calculation of pipeline volume. 

Workaround

Select only the liquid part of the system and print the System Summary report via Print Selection to use only the liquid pipes in the calculation of Total Pipeline Liquid Volume.

Resolution

A new report that can be installed with all the PIPE-FLO® Professional 16 versions is attached. Please download and install the new report for more accurate calculations around total pipeline liquid volume and total system liquid volume.